• Material Characterization

 

Francelab is offering through its worldwide partners a wide range of high technology instruments for Research and Development and Quality Control laboratories in the field of Ceramics, Composites, Electronics & Semiconductors, Geology & Mineralogy, Polymers, Nanotechnology, Metal, Rubber, Textile and Thin Films.

You are here

Error message

  • Deprecated function: The each() function is deprecated. This message will be suppressed on further calls in menu_set_active_trail() (line 2405 of /home/francela/public_html/includes/menu.inc).
  • Deprecated function: Function create_function() is deprecated in views_php_handler_field->php_post_execute() (line 131 of /home/francela/public_html/sites/all/modules/views_php/plugins/views/views_php_handler_field.inc).
  • Deprecated function: Function create_function() is deprecated in views_php_handler_field->pre_render() (line 202 of /home/francela/public_html/sites/all/modules/views_php/plugins/views/views_php_handler_field.inc).
  • Deprecated function: Function create_function() is deprecated in views_php_handler_field->pre_render() (line 202 of /home/francela/public_html/sites/all/modules/views_php/plugins/views/views_php_handler_field.inc).

EMGA-930 - Oxygen/Nitrogen/Hydrogen Combustion Analyzer

The EMGA series is a simultaneous oxygen, nitrogen & hydrogen elemental analyzer with high accuracy and repeatability suited to cutting-edge technology's R&D, as well as quality control in the market of steel, new materials, catalysts, etc.The oxygen is measured as carbon monoxide and carbon dioxide by two non-dispersive infrared detectors; The nitrogen by a thermal conductivity detector, and the hydrogen with a non-dispersive infrared detector as H2O.

Specifications

  • Measuring Range: Oxygen: 0.04 ppm-5 %
  • Measuring Range: Nitrogen: 0.04 ppm-3 %
  • Measuring Range: Hydrogen: 0.08 - 0.25 %
  • Up to 100 % is possible by decreasing the sample weight.
  • Accuracy (repeatability): Oxygen/Nitrogen: SD ≦ 0.02 ppm or more RSD ≦ 0.5 % (Reference gas)
  • Accuracy (repeatability): Hydrogen: SD ≦ 0.04 ppm or more RSD ≦ 2.0 % (Reference gas)
  • Inert Gas Fusion in Impulse Furnace:
  • Able to set the generating power 0-8.0 kW
  • Maximum temperature: 3000 Celsius
  • Measurement Time: Usually: 40 sec to 120 sec

Features:

  • Super high performance
  • User-friendly software
  • Fully supported accessories offer simple operation
  • Improved, easier to use mechanism
  • Dual Sample/Flux introduction mechanism