• Material Characterization

 

Francelab is offering through its worldwide partners a wide range of high technology instruments for Research and Development and Quality Control laboratories in the field of Ceramics, Composites, Electronics & Semiconductors, Geology & Mineralogy, Polymers, Nanotechnology, Metal, Rubber, Textile and Thin Films.

Error message

  • Deprecated function: The each() function is deprecated. This message will be suppressed on further calls in menu_set_active_trail() (line 2405 of /home/francela/public_html/includes/menu.inc).
  • Deprecated function: Function create_function() is deprecated in views_php_handler_field->php_post_execute() (line 131 of /home/francela/public_html/sites/all/modules/views_php/plugins/views/views_php_handler_field.inc).
  • Deprecated function: Function create_function() is deprecated in views_php_handler_field->pre_render() (line 202 of /home/francela/public_html/sites/all/modules/views_php/plugins/views/views_php_handler_field.inc).
  • Deprecated function: Function create_function() is deprecated in views_php_handler_field->pre_render() (line 202 of /home/francela/public_html/sites/all/modules/views_php/plugins/views/views_php_handler_field.inc).

DMA 25 desktop series

DMA 25 is desktop DMA offering a high force range and outstanding flexibility from glass transition determination to immersed tests, which makes them thermomechanical testing platforms.

Main assets

  • High force: 25 / 50 Newtons (peak)
  • Broad frequency range: from 1E-5Hz to 200 Hz
  • Broad temperature range: from -150°C to 600°C
  • Analysis of specimens with sizes representative of the materials structure
  • High performance auto-tension mode (coupled static/dynamic control) for film and 3-points bending modes
  • Thermal chamber with window
  • Reversible frame
  • Specimens immersion possible with all test modes at no extra cost
  • Easy to use
  • Can be used with a single power line connection
  • Low price

Main uses

  • DMA, TMA, simultaneous DMA/TMA tests with DYNATEST software
  • Determination of glass and secondary transitions
  • Particularly well suited to polymers and composites
  • Analysis of films and specimens with small stiffnesses
  • Tests on materials immersed in a liquid
  • R&D / Quality control
  • Education / Lab work

Excitation

  • Frequency (min) : 0.00001Hz
  • Frequency (max) : 200 Hz
  • Dynamic force (max) : 50N peak to peak
  • Dynamic displacement (max) : 6mm peak to peak

Thermal Chamber & Environment Control

  • Internal dimensions (HxWxD) : 120 mm x 140 mm x 95 mm
  • Temperature (max) : + 500°C
  • Temperature (min) : Room temperature
  • Temperature (option 1) : min. -150°C
  • Temperature (option 2) max. 600°C

Material

  • Modulus (min) : 1E3 Pa
  • Modulus (max) : 3E12 Pa
  • Measurement range : >5 decades